STEEL BUILDING CODE: UBC 97 METAL BUILDING ENCLOSURE:ENCLOSED DEAD
LOAD: ACT PSF LOAD REDUCTION: NO LIVE LOAD: 20.00 PSF EXP.FACT. Ce=1.0
Is=1.0 GROUND SNOW LOAD: 42.86 PSF SNOW IMP. FACTOR: 1.00 ROOF SNOW
LOAD: 30.00 PSF Iw=1.0 WIND VELOCITY: 70.00 MPH WIND IMP. FACTOR:
1.00 EXPOSURE CODE: C SEISMIC ZONE: 3 SEISMIC IMP. FACTOR:
1.00 SOIL PROFILE: SD - UNKNOWN Aa = N/A Av = N/A SEISMIC PROCEDURE
UTILIZED - (STATIC FORCE PROCEDURE) COLLATERAL LOAD: 0.00
PSF
NOTES: (APPLIES TO ALL ELEVATIONS) 1. DO NOT CUT, REMOVE OR RELOCATE
GIRTS OR X-BRACING. NO ADDITIONAL OPENINGS ALLOWED WITHOUT WRITTEN
APPROVAL FROM THE STEEL BUILDINGS MANUFACTURER. 2. HARDWARE SUCH AS
WINDOWS, OVERHEAD DOORS, AND ASSOCIATED ATTACHMENTS THAT ARE SUPPLIED
BY OTHERS MUST HAVE THE SAME LEVEL OF WIND RESISTANCE AS WALL
PANELS. 3. WORKERS SHALL NOT HAVE THEIR WEIGHT ON FRAMES OR
INDIVIDUAL COLUMNS UNTIL THEY HAVE BEEN SECURED WITH GIRTS AND CROSS
BRACING.
 Engineering Seal This
certification covers parts manufactured and delivered by ATY
Steel Buildings Services only and excludes parts such as doors,
windows, foundation design and erection of the metal building.