STEEL BUILDINGS INSULATION
If insulation for the steel building is desired, longer screws
may be needed.
The standard 1 X" long self-drilling screws (S.D.S) will suffice
for blanket metal building insulation up to 4' thick.
Optional 2" long self drilling screws (S.O.S.) will be needed for
blanket metal building insulation 6" thick.
For metal buildings insulation types other than fiberglass
blanket type, special screws will be needed. Please consult with
steel buildings insulation supplier on this matter.
 Metal Buildings
Insulation
CLEAN 6" STRIP OF FIBERGLASS OFF VINYL BACK AND FOLD
VINYL BACK OVER FIBERGLASS FOR MOISTURE PROOFING
NOTE: The metal buildings insulation outlined on
this page is a general representation of most typical metal
buildings insulations and their installation at metal building
. However, individual steel building manufacturers may vary slightly
in their insulation types and metal building application procedures.